Five sensor output signals, each of bandwidth 240 Hz, are
to be transmitted simultaneously by binary PCM. The signals must be sampled at
least 20% above the Nyquist rate. Framing and synchronizing requires an
additional 0.5% extra bits. The PCM encoder of Prob. 5.2-10 is used to convert
these signals before they are time-multiplexed into a single data stream.
Determine the minimum possible data rate (bits per second) that must be
transmitted, and the minimum bandwidth required to transmit the multiplex
signal.